History-fieldPoynworks with VSimBase, VSimEM, VSimPD, VSimPA, and VSimMD licenses.
indicates Vorpal should calculate the integrated Poynting vector (energy
flux) through the area defined by the upperBounds and
lowerBounds of two fields.
lowerBoundsDefines a surface area. Vorpal calculates the integrated Poynting vector through this surface area.
upperBoundsDefines a surface area. Vorpal calculates the integrated Poynting vector through this surface area.
fields (string vector, required)Indicates the fields for a History kind that reports data for a multiple fields. Exactly two fields must be specified in the fields keyword. The first one is the electric field. The second one is the associated magnetic field.
<History fieldPoynPt>
kind = fieldPoyn
lowerBounds = [1 1 1]
upperBounds = [1 3 3]
fields = [multiField.elecField multiField.magField]
</History>