History-fieldPoyn
works with VSimBase, VSimEM, VSimPD, VSimPA, and VSimMD licenses.
indicates Vorpal should calculate the integrated Poynting vector (energy
flux) through the area defined by the upperBounds
and
lowerBounds
of two fields.
lowerBounds
Defines a surface area. Vorpal calculates the integrated Poynting vector through this surface area.
upperBounds
Defines a surface area. Vorpal calculates the integrated Poynting vector through this surface area.
fields (string vector, required)
Indicates the fields for a History kind that reports data for a multiple fields. Exactly two fields must be specified in the fields keyword. The first one is the electric field. The second one is the associated magnetic field.
<History fieldPoynPt>
kind = fieldPoyn
lowerBounds = [1 1 1]
upperBounds = [1 3 3]
fields = [multiField.elecField multiField.magField]
</History>