- MultiField
MultiField¶
Advanced method for simulations that enables precise user control over fields and algorithms.
A MultiField object contains a trio of sub-objects:
Field
FieldUpdater
UpdateStep
The MultiField object facilitates development and application of new algorithms by providing separate specification of the data (
Field
), the update operations on those fields (FieldUpdater
), and the algorithmic sequencing of those update operations (UpdateStep
). A crucial feature ofUpdateStep
use is that instances ofUpdateStep
also govern communication during parallel processing. Additional special cases of these sub-objects also exist, includingInitialUpdateStep
(an update operation done once at the begining),FieldMultiUpdater
(a special treatment of fields with more than one component), andPmlRegion
(a special absorber boundary object for electromagnetic simulation).This additional level of control proves useful in two general circumstances. First, it allows the user to make significant alterations in the sequencing of the traditional electrostatic and electromagnetic algorithms. These changes might include custom sources and boundary conditions, custom fields for particle forces, diagnostics, or post processing purposes, and/or custom combinations of different solvers in the same simulation. One example is to swap out the traditional electromagnetic solvers in favor of GPU accelerated solvers. A second useful circumstance is that it provides a means to create arbitrary partial differential equaion (PDE) solvers, beyond the commonly used electrostatic and electromagnetic simulations. One example provided with the software shows how to construct a solver for the heat conduction problem.
Electromagnetics Using MultiField¶
The traditional electromagnetic algorithm contains an electric
Field
and a magneticField
, two instances ofFieldUpdater
: Ampere (which updates electric field) and Faraday (which updates magnetic field), and two instances ofUpdateStep
, one for each of theFieldUpdater
. AnUpdateStep
can designate one-and-only-one field for parallel-process messaging. ThereforeUpdateStep
must be used twice, once to update-and-message the electric field, and again to update-and-message the magnetic field.From this backbone electromagnetic algorithm, several commonly used enhancements arise and are found in the following examples:
Metallic Boundaries and the
FieldUpdater
deyMittraUpdaterWhen there are metallic boundaries, an additonal
FieldUpdater
(deyMittraUpdater) applies a cut-cell boundary condition to the magnetic field. This additionalFieldUpdater
is usually grouped in the sameUpdateStep
as the FaradayFieldUpdater
, so there remain only two UpdateSteps.Particles and the Magnetic Field
UpdateStep
When there are particles, the magnetic field
UpdateStep
is usually split, so that half is done at the end of the cycle, in order to have electric and magnetic fields at the same time during the cycle for particle forces. The remaining half of the update is then done at the beginning of the next cycle, resulting in three ofUpdateStep
instead of two.Particles and Assisted Particle Force Computation with
Field
DefinitionsWhen there are particles, a second set of electric and magnetic
Field
definitions centered at the nodes may be introduced to assist in computing particle forces. TheedgeToNodeVec
FieldUpdater
andfaceToNodeVec
FieldUpdater
provide this functionality, and two new uses ofUpdateStep
, one for each newField
, are placed at the end of the cycle.Outgoing Wave Boundary Conditions with an Open
FieldUpdater
Outgoing wave boundary conditions can be applied to the electric field with an open
FieldUpdater
. This additionalFieldUpdater
is usually grouped in the sameUpdateStep
as the AmpereFieldUpdater
.Dielectric Loss, Matched magnetic loss, and Traditional Bulk Electrical Conductivity
Dielectric loss (complex dielectric), matched magnetic loss, and traditional bulk electrical conductivity, are added as additional uses of
FieldUpdater
, usually instances ofSTFuncUpdater
, just before and just after Ampere and Faraday, and usually grouped together with the applicable fieldUpdateStep
.Electric Voltage and Current Sources Addition
Electric voltage and current sources are added as additional uses of
FieldUpdater
, usually instances ofSTFuncUpdater
, grouped with and applied just before or just after the AmpereUpdateStep
.
Blocks Contained Inside MultiField Blocks¶
A MultiField is described between <MultiField nameOfThisMultiField> and </MultiField> tags. In addition to MultiField parameters, the MultiField block must contain the following blocks:
Field FieldUpdater FieldUpdateStep
and may in some circumstances contain the following additional blocks:
InitialUpdateStep
FieldMultiUpdater
PmlRegion
Instances of
Field
are not required to appear in occurances ofFieldUpdater
, however, anyFieldUpdater
must appear at least once in anUpdateStep
or anInitialUpdateStep
.
MultiField Parameters¶
- kind
Type of MultiField algorithm; one of:
- Null:
Works with VSimBase, VSimEM, VSimPD, VSimPA, and VSimVE licenses.
no kind parameter; this is the default. The default behavior of not specifying a kind parameter for a MultiField is usually the correct choice for simulations.
lightFrameEnvelopeMultiField
:Works with VSimPA license.
Implements the Laser Envelope Model. Fields can be discretized on Laser Envelope Model grids and interpolated to particle positions. When using the Envelope Model with particles, the species should be set to
kind = envBoris
. ThislightFrameEnvelopeMultiField
kind of MultiField creates special grids that have the same size and spacing as the main grid, but that move in the +x direction at the speed of light:
active grid
:The position of this grid is initialized to be offset from the main grid by \(c\Delta t/2\) in the \(x\) direction. It is shifted by \(c\Delta t\) in the \(+x\) direction every timestep.
alternate grid
:This grid is initially offset by \(-c\Delta t/2\), and is shifted by \(c\Delta t\) in the \(+x\) direction every timestep.
activeLightFrameFields
Specifies the fields which exist on the active light frame grid.
alternateLightFrameFields
:Specifies the fields which exist on the alternate light frame grid.
- updateStepOrder (optional, string vector)
This specifies the order in which to execute the UpdateSteps. By default, if this attribute is not given, the UpdateSteps are executed in the order in which they are specified in the input file.
- shiftUpdaters (optional, integer; default = false)
If
true
, the updaters in the MultiField will be shifted along with the fields. This is only relevant for updaters that rely on GridBoundary information that might shift.
- restoreTimeFromField (optional, string)
Name of the field from which MultiField will get the current time when restoring from a dump.
restoreTimeFromField
is required for cases in which MultiField cannot automatically determine the proper field from which to restore. MultiField can make this determination if there is a field updated by an updater which is specified in an UpdateStep withtoDtFrac = 1
.