- fieldSqrDiagUpdater
fieldSqrDiagUpdater¶
Works with VSimBase, VSimEM, VSimPD, VSimPA, and VSimVE licenses.
FieldMultiUpdater
that computes an integral over the
sum of the squares of the specified fields, for each specified
component; i.e., for each component \(i\),
The fields \(\mathbf{f}^{(1)}, \mathbf{f}^{(2)},
\mathbf{f}^{(3)},\ldots, \mathbf{f}^{(n)}\) used in the integral
are given by the readFields
parameter. The calculation
is written to the standard output of the
run. fieldSqrDiagUpdater
is useful for measuring field
energy and reflected components.
fieldSqrDiagUpdater Parameters¶
The fieldSqrDiagUpdater
takes the lowerBounds
and
upperBounds
parameters of FieldUpdater and the
.components
parameter of FieldMultiUpdater, as well as
the following parameters:
- readFields (required string vector)
The names of the fields for which to compute the integral.
- factor (optional float, default = 1.0)
Factor a by which to multiply the integral.
- writePeriod (optional integer, default = 0)
Frequency which to write out the calculation. A
writePeriod
of1
will write out the calculation at each time step.
Example fieldSqrDiagUpdater Block¶
<FieldMultiUpdater E_energy>
kind = fieldSqrDiagUpdater
writePeriod = 20
factor = E_ENERGY_FACTOR
components = [0 1 2]
contractFromBottomInNonComponentDir = 1
lowerBounds = [0 0 0]
upperBounds = [NX_TOT NY_TOT NZ_TOT]
readFields = [elecField]
</FieldMultiUpdater>