FieldDynamics for Prescribed Fields Simulations

This page describes the Field options available for prescribed field simulations, that is, when the field solver in the Basic Settings element is set to prescribed fields.

Fields

externalElectricField

The Electric Field as prescribed by the user.

kind (un-editable)

External Electric Field

description

A space to provide a descriptive comment for the field.

field type

electric field(cannot be changed)

field specification

Either import h5 file or function defined.

  • function defined

    Allows for manual specification of each component of the field

    component 0:

    The function defining the field in the 0th component. Can be a time varying function

    component 1:

    The function defining the field in the 1st component. Can be a time varying function

    component 2:

    The function defining the field in the 2nd component. Can be a time varying function

  • import h5 file A vis schema compliant h5 file. It does require that the file be in the same directory as the simulation. An error message will be provided if the file fails to import.

    filename:

    The name of the .hdf5 file to be imported. The file name must be specified as simulationName_fieldName_dumpNum.h5

    lower bound 0:

    The cell index of the 0th component lower bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    lower bound 1:

    The cell index of the 1st component lower bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    lower bound 2:

    The cell index of the 2nd component lower bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    upper bound 0:

    The cell index of the 0th component upper bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    upper bound 1:

    The cell index of the 1st component upper bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    upper bound 2:

    The cell index of the 2nd component upper bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

externalMagneticField

The Magnetic Field as prescribed by the user.

kind (un-editable)

External Magnetic Field

description

A space to provide a descriptive comment for the field.

field type

magnetic (cannot be changed)

field specification

Either import h5 file or function defined.

  • function defined

    Allows for manual specification of each component of the field

    component 0:

    The function defining the field in the 0th component. Can be a time varying function

    component 1:

    The function defining the field in the 1st component. Can be a time varying function

    component 2:

    The function defining the field in the 2nd component. Can be a time varying function

  • import h5 file A vis schema compliant h5 file. It does require that the file be in the same directory as the simulation. An error message will be provided if the file fails to import.

    filename:

    The name of the .hdf5 file to be imported. The file name must be specified as simulationName_fieldName_dumpNum.h5

    lower bound 0:

    The cell index of the 0th component lower bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    lower bound 1:

    The cell index of the 1st component lower bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    lower bound 2:

    The cell index of the 2nd component lower bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    upper bound 0:

    The cell index of the 0th component upper bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    upper bound 1:

    The cell index of the 1st component upper bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

    upper bound 2:

    The cell index of the 2nd component upper bound of the source field, to be imported to the matching index in the simulation. If left not applicable the entire field will be imported.

Time Dependence Properties

Time Dependence is available for prescribed field simulations.

E-Field multiplier

Time dependent function to be applied at each time step to the electric field.

B-Field multiplier

Time dependent function to be applied at each time step to the magnetic field.